靜電消除器檢測儀TREK 156A

TREK156A為31/2LED顯示,TREK157LCD顯示,TREK158彩色LCD圖形顯示

靜電消除器檢測儀TREK 156A

靜電消除器檢測儀TREK 156A

Trek Model 156A 離子風扇檢測儀是定量地分析離子風扇工作效能的,156A具有兩種檢測模式(衰減時間和平衡度), 在衰減模式中可以自由設定啟始和結束電壓,有大小兩種測試板可供選擇,符合不同測試需要

TREK 156A防靜電設備檢測儀
離子平衡測量儀,主要用于監控離子產生器及離子風扇的工作效率。
Model 156A & Model 156A/1 CHARGED-PLATE MONITOR
The Trek Model 156A Charged-Plate Monitor System is designed
to provide quantitative measurements of the effectiveness of
air ionization systems, as to audit ionizer performance.
The Model 156A employs a revolutionary charged-plate monitor
design that utilizes an ultrahigh-impedance, high-voltage
follower to monitor the ion collecting plate voltage. This
technique provides very high accuracy and virtually infinite
impedance loading of the plate, while allowing the ion
collecting plate to be charged and monitored through the same
small-diameter connection. This technique also makes the
measurement capacitance independent of the physical size and
 shape of the ion plate. Therefore, the size and shape of an
 ion collecting plate, as well as the measurement capacitance,
 may be customer specified to match a particular ESD-sensitive
 device within a manufacturing process, or it may be made to
 conform to the EOS/ESD Association Standard STM3.1-2000.
The Model 156A features two modes of operation, a decay mode
with easy-to-program start and stop voltages, and a float mode. For decay mode operation, the ion collecting plate is precharged to a level above the programmed START voltage. The time required to discharge the ion collecting plate from the programmed START voltage to the programmed STOP voltage due to incident ion flow to the ion collecting plate from the measured ion field is indicated by the Model 156A. In the float mode of operation, the plate is initially discharged to zero and then allowed to float to the voltage level dictated by incident ion flow to the ion collecting plate from the measured ion field.
The simplicity of the design of the Model 156A makes it very
reliable and completely portable. The Model 156A is powered by
 an internal rechargeable battery that offers 8 hours of
operation from a full charge.
The Trek Model 156A/1 has a serial interface port to connect
with a computer. Computer Software allows the operator to
program test sequences, save, or retrieve test results. Any
series of tests can be duplicated, analyzed, programmed or
retrieved using PC based software.
PERFORMANCE
•Monitored Voltage Range
0 to ±1100 V DC or peak AC.
•Small Signal Bandwidth (-3 dB)
DC to 1 kHz (measured at 20 V p-p).
•Large Signal Bandwidth
DC to 10 Hz (measured at 2000 V p-p).
•Zero Stability (referred to plate voltage)
Drift with Time (no incident ion flow)
Less than 6 V/minute.
•Drift with Temperature
Less than 10 mV/°C, noncumulative.
•Decay Mode Thresholds
oStart Voltage
156A unit,156A/1 unit and software programmable from 1 to
±1000 V in 1 V increments.
oStart Accuracy
156A unit,156A/1 unit and software within ±1 V of programmed
start voltage.
oStop Voltage
156A unit,156A/1 unit and software software programmable from
 0 to ±999 V in 1 V increments.
oStop Accuracy
156A unit,156A/1 unit and software within ±1 V of programmed
stop voltage.
•Plate Self-Discharge (unpolarized)
Less than 12 V/minute.